Master Battery on (if req)
Standby power guard closed (if req)
Fire tests
Start APU
Check APU Gen Voltage on Voltmeter
Left Forward Fuel Pump on for APU if APU selected as power source
Left Center Fuel Pump if center fuel quantity > 1000 pounds (APU only)
Wheel well fire test (only if AC Power Avail)
Position light On
Yaw
damper On
Flight Control Switches On
Galley power On
Window heat test and window heat On
Eng Hyd Pump A and B On
Emergency lights Arm
Trim air On
Recirc fans Auto
Autopilot disengage light test
GPWS test
Cargo fire test
Push master fire warning
VHF 1 and 2 test
TCAS test (IRS must be aligned first)
Overspeed test
Verify Parking brake Set
Fasten seatbelts + no smoking Auto
Pack Auto
Isolation valve Open
Engine Bleeds On
APU bleed On
Flight Altitude in Pressurization Controller Set
Landing Altitude in Pressurization Controller Set
Ignition
selection switch Set (cycle)
Logo light if night On
Flight directors On
Autobrake RTO
Fuel flow Reset
Lower display to SYS
Verify FMC pages
CWP: Probe Heat on
Call "Ready for Checklist"